Wednesday, January 1, 2014

Install VCS on RHEL 5

Install VCS on RHEL 5


Host name  :    node1.example.com
Host name  :    node2.example.com
OS         :    RHEL 5.6 64 bit

Make sure both the servers time is sync up.
Make sure host names are resolving. Edit /etc/hosts files on both the servers.

# more /etc/hosts
127.0.0.1               localhost.localdomain localhost
::1             localhost6.localdomain6 localhost6
192.168.80.21   node1.example.com       node1
192.168.80.22   node2.example.com       node2

Installation package has been copied on node1 /opt folder. Enable execute permission on that folder.

# chmod +x VRTS_SF_HA_Solutions_5.1_SP1_RHEL/ -R

Pre check the pre-requisite on both the servers.


# ./installer -precheck

1)  Veritas Dynamic Multi-Pathing (DMP)
     2)  Veritas Cluster Server (VCS)
     3)  Veritas Storage Foundation (SF)
     4)  Veritas Storage Foundation and High Availability (SFHA)
     5)  Veritas Storage Foundation Cluster File System (SFCFS)
     6)  Veritas Storage Foundation Cluster File System/HA (SFCFSHA)
     7)  Veritas Storage Foundation for Oracle RAC (SFRAC)
     8)  Veritas Storage Foundation Cluster File System for Oracle RAC (SFCFS RAC)
     9)  Symantec VirtualStore (SVS)
    10)  Symantec Product Authentication Services (AT)
     b)  Back to previous menu

Select a product to perform pre-installation check for: [1-10,b,q] 3

Verifying systems: 100%

    Estimated time remaining: 0:00                                                        8 of 8

    Checking system communication ............................... Done
    Checking release compatibility .............................. Done
    Checking installed product .................................. Done
    Checking prerequisite patches and rpms ...................... Done
    Checking platform version ................................... Done
    Checking file space ......................................... Done
    Performing product license checks ........................... Done
    Performing product prechecks ................................ Done

Precheck report completed

System verification checks completed successfully

No issues found in prechecks

Would you like to install SF on node1 node2? [y,n,q] (n) n

installer log files, summary file, and response file are saved at:

        /opt/VRTS/install/logs/installer-201401011724IFa

Now we can start the VCS installation


# ./installer node1 node2

Task Menu:

    P) Perform a Pre-Installation Check     I) Install a Product
    C) Configure an Installed Product       G) Upgrade a Product
    O) Perform a Post-Installation Check    U) Uninstall a Product
    L) License a Product                    S) Start a Product
    D) View Product Descriptions            X) Stop a Product
    R) View Product Requirements            ?) Help

Enter a Task: [P,I,C,G,O,U,L,S,D,X,R,?] I ß Press “I” and enter

     1)  Veritas Dynamic Multi-Pathing (DMP)
     2)  Veritas Cluster Server (VCS)
     3)  Veritas Storage Foundation (SF)
     4)  Veritas Storage Foundation and High Availability (SFHA)
     5)  Veritas Storage Foundation Cluster File System (SFCFS)
     6)  Veritas Storage Foundation Cluster File System/HA (SFCFSHA)
     7)  Veritas Storage Foundation for Oracle RAC (SFRAC)
     8)  Veritas Storage Foundation Cluster File System for Oracle RAC (SFCFS RAC)
     9)  Symantec VirtualStore (SVS)
    10)  Symantec Product Authentication Services (AT)
     b)  Back to previous menu

Select a product to install: [1-10,b,q] 4 ß Press “4” and enter

Do you agree with the terms of the End User License Agreement as specified in the
storage_foundation_high_availability/EULA/en/EULA_SFHA_Ux_5.1SP1.pdf file present on media? [y,n,q,?] y ß Press “y” and enter

1)  Install minimal required Veritas Storage Foundation and High Availability rpms - 378 MB required
     2)  Install recommended Veritas Storage Foundation and High Availability rpms - 581 MB required
     3)  Install all Veritas Storage Foundation and High Availability rpms - 618 MB required
     4)  Display rpms to be installed for each option

Select the rpms to be installed on all systems? [1-4,q,?] (2) ß Use default option

Enter the 64 bit RHEL5 system names separated by spaces: [q,?] node1 node2 ß enter servers hostname

Estimated time remaining: 0:00                                                                                          8 of 8

    Checking system communication ........................................................................................... Done
    Checking release compatibility .......................................................................................... Done
    Checking installed product .............................................................................................. Done
    Checking prerequisite patches and rpms .................................................................................. Done
    Checking platform version ............................................................................................... Done
    Checking file space ..................................................................................................... Done
    Performing product license checks ....................................................................................... Done
    Performing product prechecks ............................................................................................ Done

System verification checks completed successfully


Rpm               Rpm Description

VRTSvlic          Veritas Licensing
VRTSperl          Veritas Perl 5.10.0 Redistribution
VRTSspt           Veritas Software Support Tools by Symantec
VRTSvxvm          Veritas Volume Manager Binaries
VRTSaslapm        Volume Manager - ASL/APM
VRTSob            Veritas Enterprise Administrator Service by Symantec
VRTSsfmh          Veritas Storage Foundation Managed Host by Symantec
VRTSvxfs          Veritas File System
VRTSatClient      Symantec Product Authentication Service Client
VRTSatServer      Symantec Product Authentication Service
VRTSllt           Veritas Low Latency Transport
VRTSgab           Veritas Group Membership and Atomic Broadcast
VRTSvxfen         Veritas I/O Fencing by Symantec
VRTSamf           Veritas Asynchronous Monitoring Framework by Symantec
VRTSvcs           Veritas Cluster Server
VRTSvcsag         Veritas Cluster Server Bundled Agents by Symantec
VRTSvcsdr         Veritas Cluster Server Disk Reservation Modules
VRTSvcsea         Veritas Cluster Server Enterprise Agents by Symantec
VRTSdbed          Veritas Storage Foundation Databases
VRTSodm           Veritas Oracle Disk Manager

Press [Enter] to continue: ß Enter here

Installing SFHA: 100%

    Estimated time remaining: 0:00                                                                                        23 of 23

    Performing SFHA preinstall tasks ........................................................................................ Done
    Installing VRTSvlic rpm ................................................................................................. Done
    Installing VRTSperl rpm ................................................................................................. Done
    Installing VRTSspt rpm .................................................................................................. Done
    Installing VRTSvxvm rpm ................................................................................................. Done
    Installing VRTSaslapm rpm ............................................................................................... Done
    Installing VRTSob rpm ................................................................................................... Done
    Installing VRTSvxfs rpm ................................................................................................. Done
    Installing VRTSatClient rpm ............................................................................................. Done
    Installing VRTSatServer rpm ............................................................................................. Done
    Installing VRTSllt rpm .................................................................................................. Done
    Installing VRTSgab rpm .................................................................................................. Done
    Installing VRTSvxfen rpm ................................................................................................ Done
    Installing VRTSamf rpm .................................................................................................. Done
    Installing VRTSvcs rpm .................................................................................................. Done
    Installing VRTSvcsag rpm ................................................................................................ Done
    Installing VRTSvcsdr rpm ................................................................................................ Done
    Installing VRTSvcsea rpm ................................................................................................ Done
    Installing VRTSdbed rpm ................................................................................................. Done
    Installing VRTSodm rpm .................................................................................................. Done
    Installing VRTSsfmh rpm ................................................................................................. Done
    Performing SFHA postinstall tasks ....................................................................................... Done
    Copying installer libraries and scripts ................................................................................. Done

Veritas Storage Foundation and High Availability Install completed successfully

1)  Enter a valid license key
     2)  Enable keyless licensing and complete system licensing later

How would you like to license the systems? [1-2,q] (2) ß choose the default and press enter

1)  SF Standard HA
     2)  SF Enterprise HA
     b)  Back to previous menu

Select product mode to license: [1-2,b,q,?] (1) ß choose the default and press enter

Would you like to enable the Veritas Volume Replicator? [y,n,q] (n) ß press “n” and enter

Registering SFHA license

Would you like to configure SFHA on node1 node2? [y,n,q] (n) y ß type “y” and enter

I/O Fencing

It needs to be determined at this time if you plan to configure I/O Fencing in enabled or disabled mode, as well as help in
determining the number of network interconnects (NICS) required on your systems. If you configure I/O Fencing in enabled mode,
only a single NIC is required, though at least two are recommended.

A split brain can occur if servers within the cluster become unable to communicate for any number of reasons. If I/O Fencing is
not enabled, you run the risk of data corruption should a split brain occur. Therefore, to avoid data corruption due to split
brain in CFS environments, I/O Fencing has to be enabled.

If you do not enable I/O Fencing, you do so at your own risk

See the Administrator's Guide for more information on I/O Fencing

Do you want to configure I/O Fencing in enabled mode? [y,n,q,?] (y) n ß type “n” and press enter

To configure VCS, answer the set of questions on the next screen.

When [b] is presented after a question, 'b' may be entered to go back to the first question of the configuration set.

When [?] is presented after a question, '?' may be entered for help or additional information about the question.

Following each set of questions, the information you have entered will be presented for confirmation.  To repeat the set of
questions and correct any previous errors, enter 'n' at the confirmation prompt.

No configuration changes are made to the systems until all configuration questions are completed and confirmed.

Press [Enter] to continue:

A unique cluster name
        A unique cluster ID number between 0-65535
        Two or more NICs per system used for heartbeat links

        One or more heartbeat links are configured as private links
        You can configure one heartbeat link as a low-priority link

All systems are being configured to create one cluster.

Enter the unique cluster name: [q,?] mycluster ß type the cluster name and press enter
Enter a unique cluster ID number between 0-65535: [b,q,?] 1 ß type the cluster ID and press enter

1)  Configure heartbeat links using LLT over Ethernet
     2)  Configure heartbeat links using LLT over UDP
     3)  Automatically detect configuration for LLT over Ethernet
     b)  Back to previous menu

How would you like to configure heartbeat links? [1-3,b,q,?] (1) ß press “1” and enter

Discovering NICs on node1 ................................................................ Discovered eth0 eth1 eth2 eth3 sit0

Enter the NIC for the first private heartbeat link on node1: [b,q,?] (sit0) eth1
eth1 has an IP address configured on it. It could be a public NIC on node1.
Are you sure you want to use eth1 for the first private heartbeat link? [y,n,q,b,?] (n) y
Would you like to configure a second private heartbeat link? [y,n,q,b,?] (y) y
Enter the NIC for the second private heartbeat link on node1: [b,q,?] (sit0) eth2
eth2 has an IP address configured on it. It could be a public NIC on node1.
Are you sure you want to use eth2 for the second private heartbeat link? [y,n,q,b,?] (n) y
Would you like to configure a third private heartbeat link? [y,n,q,b,?] (n)
Do you want to configure an additional low-priority heartbeat link? [y,n,q,b,?] (n) y
Enter the NIC for the low-priority heartbeat link on node1: [b,q,?] (eth0)
Are you using the same NICs for private heartbeat links on all systems? [y,n,q,b,?] (y) y

Cluster information verification:

        Cluster Name:      mycluster
        Cluster ID Number: 1
        Private Heartbeat NICs for node1:
                link1=eth1
                link2=eth2
        Low-Priority Heartbeat NIC for node1:
                link-lowpri1=eth0
        Private Heartbeat NICs for node2:
                link1=eth1
                link2=eth2
        Low-Priority Heartbeat NIC for node2:
                link-lowpri1=eth0

Is this information correct? [y,n,q,b,?] (y) ß type “y” and press enter

Virtual IP can be specified in RemoteGroup resource, and can be used to connect to the cluster using Java GUI
The following data is required to configure the Virtual IP of the Cluster:

        A public NIC used by each system in the cluster
        A Virtual IP address and netmask

Do you want to configure the Virtual IP? [y,n,q,?] (n) y
Active NIC devices discovered on node1: eth0 eth1 eth2 eth3
Enter the NIC for Virtual IP of the Cluster to use on node1: [b,q,?] (eth0)
Is eth0 to be the public NIC used by all systems? [y,n,q,b,?] (y) y
Enter the Virtual IP address for the Cluster: [b,q,?] 192.168.80.100
Enter the NetMask for IP 192.168.80.100: [b,q,?] (255.255.255.0)

Cluster Virtual IP verification:

        NIC: eth0
        IP: 192.168.80.100
        NetMask: 255.255.255.0

Is this information correct? [y,n,q] (y) ß type “y” and press enter

Would you like to configure VCS to use Symantec Security Services? [y,n,q] (n)

The following information is required to add VCS users:

        A user name
        A password for the user
        User privileges (Administrator, Operator, or Guest)

Do you want to set the username and/or password for the Admin user
(default username = 'admin', password='password')? [y,n,q] (n) ß type “n” and press enter

VCS User verification:

        User: admin     Privilege: Administrators

        Passwords are not displayed

Is this information correct? [y,n,q] (y) ß type “y” and press enter

The following information is required to configure SMTP notification:

        The domain-based hostname of the SMTP server
        The email address of each SMTP recipient
        A minimum severity level of messages to send to each recipient

Do you want to configure SMTP notification? [y,n,q,?] (n) ß type “n” and press enter


The following information is required to configure SNMP notification:

        System names of SNMP consoles to receive VCS trap messages
        SNMP trap daemon port numbers for each console
        A minimum severity level of messages to send to each console

Do you want to configure SNMP notification? [y,n,q,?] (n) ß type “n” and press enter


All SFHA processes that are currently running must be stopped

Do you want to stop SFHA processes now? [y,n,q,?] (y) ß type “y” and press enter

Stopping SFHA: 100%

    Estimated time remaining: 0:00                                                                                          9 of 9

    Performing SFHA prestop tasks ........................................................................................... Done
    Stopping had ............................................................................................................ Done
    Stopping hashadow ....................................................................................................... Done
    Stopping CmdServer ...................................................................................................... Done
    Stopping amf ............................................................................................................ Done
    Stopping vxfen .......................................................................................................... Done
    Stopping gab ............................................................................................................ Done
    Stopping llt ............................................................................................................ Done
    Stopping vxatd .......................................................................................................... Done

Veritas Storage Foundation and High Availability Shutdown completed successfully

Starting SFHA: 100%

    Estimated time remaining: 0:00                                                                                        18 of 18

    Performing SFHA configuration ........................................................................................... Done
    Starting vxdmp .......................................................................................................... Done
    Starting vxio ........................................................................................................... Done
    Starting vxspec ......................................................................................................... Done
    Starting vxconfigd ...................................................................................................... Done
    Starting vxesd .......................................................................................................... Done
    Starting vxrelocd ....................................................................................................... Done
    Starting vxconfigbackupd ................................................................................................ Done
    Starting vxportal ....................................................................................................... Done
    Starting fdd ............................................................................................................ Done
    Starting llt ............................................................................................................ Done
    Starting gab ............................................................................................................ Done
    Starting had ............................................................................................................ Done
    Starting hashadow ....................................................................................................... Done
    Starting CmdServer ...................................................................................................... Done
    Starting vxdbd .......................................................................................................... Done
    Starting vxodm .......................................................................................................... Done
    Performing SFHA poststart tasks ......................................................................................... Done

Veritas Storage Foundation and High Availability Startup completed successfully

Would you like to send the information about this installation to Symantec to help improve installation in the future? [y,n,q,?]
(y) n ß type “n” and press enter

installer log files, summary file, and response file are saved at:

        /opt/VRTS/install/logs/installer-201401020035dhA


Run the following command to check the veritas cluster status

# /opt/VRTSvcs/bin/hastatus -sum

-- SYSTEM STATE
-- System               State                Frozen

A  node1                RUNNING              0
A  node2                RUNNING              0

-- GROUP STATE
-- Group           System               Probed     AutoDisabled    State

B  ClusterService  node1                Y          N               ONLINE
B  ClusterService  node2                Y          N               OFFLINE

# ps -ef | grep -i had
root     10417     1  0 00:45 ?        00:00:00 /opt/VRTSvcs/bin/had
root     10426     1  0 00:45 ?        00:00:00 /opt/VRTSvcs/bin/hashadow

# ip a | grep -i 192.168.80.100 --color
    inet 192.168.80.100/24 scope global secondary eth0:0

-----Veritas cluster suite installation completed successfully---

No comments: